The PG circuit breaker range, from 5 to 60 A, (1 Ph + N) or (3 Ph + N), with or without earth leakage protection (300 mA - 500 mA or 650 mA), offers the right product to fit every type of installation.

operating principles

■service connections are the interface between the Utility and the end- user customer.
■they connect the customer’s electrical installation to the power distribution network.

Advantages

■low-cost product, suitable for conventional service connections.
■multiple rating device.
■several levels of earth leakage sensitivity.
■compiles with the French NFC 61 450 standard.

Protection of The Consumer's 'Installation

-against overloads

-against short-circuits

-against the risks of electrocution

Technical Data Sheet

safety
■thermal compensation
□the pôle settings are not affected by the ambient température.
■residual current device
□highly reliable, self-powered System
□immunized against voltage surges of atmospheric origin
□unintemjpted power supply for greater user convenience.
■prévention of overvoltage
□the neutral pôle is designed to close first and open last to maintain a fixed potential.
electrical characteristics
■earth leakage break time
□ < 0.2 s for 1 lAn
□ < 0.1 s for 1 lAn
■ earth leakage tripping □ 300 mA, 500 mA or 650 mA,
■operating température
□- 5 • C to + 55 0 C
■voltage drop
1 pôle + neutral < 0.9 V
■ insulation résistance □
>2MO
■ dielectric withstand
□ 2 kV AC for 1 minute
4 kV between pôles and frame
■ tripping curve
C type
easy operation
■operation in ail positions
H ON/OFF control by push-button
■rating easily changed
■lead-sealable terminal shields
■captive terminal screws
■pivoting terminais
■copper cables up to 35 mm2
■neutral identified in blue
environment
■IP 40 protection

other characteristics
□8 days in damp chamber (CCTU4 cycle)
■weight :
□2-pole : 0.6 kg - 4-pole : 1.0 kg

Low Voltage Service Connections

The DDI circuit breaker range, from 5 to60A, (1 Ph + N) or (3 Ph + N), with or without earth leakage protection 300mA 500mA 650mA offers the right product to fit every type of installation.

Protection against nuisance tripping

■Immunized against voltage surges of atmospheric origin
■Uninterrupted power supply for greater user convenience

Advantages

■multiple rating device
■temperature-compensated
■highly sensitive earth leakage protection
■complies with international standards CEE 27, EN 60898 et IEC 1009

Prévention of overvoltage

■The neutral pôle is designed to close first and open last to maintain a fixed potential.

Display of contact position

■Green indicator: contact open
■Red indicator: contact closed

Safety checking

■The test button may be used to simulate an earth leakage fault, thereby providing a simple way to check the System.

Easy operation

- operation in ail positions
■ON/OFF contrai by push-button
■rating easily changed
■lead-sealable terminal shields
■captive terminal screws
■pivoting terminais
■copper cables up to 35 mm2
■neutral identified in blue